Motor Temperature Sensor Type / Mot_Temp_Sens Type; Macro Binector Input (Bi) / Macro Bi; Macro Binector Input (Bi) For Tms / Macro Bi Tm - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Notice:
When changing over from one technological unit into another, or when changing the reference parameter, a
changeover is not made.
p0601[0...n]

Motor temperature sensor type / Mot_temp_sens type

DC_CTRL,
Can be changed: C2(3), U, T
DC_CTRL_R,
Data type: Integer16
DC_CTRL_R_S,
P-Group: Motor
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Sets the sensor type for the motor temperature monitoring.
Value:
0:
2:
Dependency:
Refer to: r0458
p0700[0...n]

Macro Binector Input (BI) / Macro BI

DC_CTRL,
Can be changed: C2(1), T
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Commands
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Runs the corresponding macro files.
The binector inputs of the corresponding command data set are appropriately interconnected.
The selected macro file must be available on the memory card/device memory.
Example:
p0700 = 6 --> macro file PM000006.ACX is run.
Dependency:
Refer to: p0015, p1000, p1500, r8571
Notice:
No errors were issued during quick commissioning (p3900 = 1) when writing to parameters of the QUICK_IBN group!
When executing a specific macro, the corresponding programmed settings are made and become active.
Note:
The macros in the specified directory are displayed in r8571. r8571 is not in the expert list of the commissioning
software.
Macros available as standard are described in the technical documentation of the particular product.
BI: Binector Input
CDS: Command Data Set
p0700

Macro Binector Input (BI) for TMs / Macro BI TM

TM15DI_DO, TM31
Can be changed: C2(1), T
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
0
Description:
Runs the corresponding macro files.
The selected macro file must be available on the memory card/device memory.
Example:
p0700 = 6 --> macro file PM000006.ACX is run.
Dependency:
Refer to: r8571
Notice:
No errors were issued during quick commissioning (p3900 = 1) when writing to parameters of the QUICK_IBN group!
When executing a specific macro, the corresponding programmed settings are made and become active.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
No sensor
KTY84
Calculated: -
Dyn. index: MDS
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
999999
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
999999
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
95

Hide quick links:

Advertisement

Table of Contents