Bico Counter Drive Object / Bico Counter Do; Faults Acknowledge Drive Object / Faults Ackn Do; Master Control Mode Selection / Pcctrl Mode Select; Parameter Count / Parameter No. - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r3979

BICO counter drive object / BICO counter DO

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Commands
DC_CTRL_S, TM150,
Not for motor type: -
TM15DI_DO, TM31
Min
-
Description:
Displays the counter reading for modified BICO interconnections on this drive object.
The counter is incremented by one for each modified BICO interconnection.
p3981

Faults acknowledge drive object / Faults ackn DO

All objects
Can be changed: U, T
Data type: Unsigned8
P-Group: Messages
Not for motor type: -
Min
0
Description:
Setting to acknowledge all active faults of a drive object.
Notice:
Safety messages cannot be acknowledged using this parameter.
Note:
Parameter should be set from 0 to 1 to acknowledge.
After acknowledgement, the parameter is automatically reset to 0.
p3985

Master control mode selection / PcCtrl mode select

DC_CTRL,
Can be changed: U, T
DC_CTRL_R,
Data type: Integer16
DC_CTRL_R_S,
P-Group: Setpoints
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Sets the mode to change over the master control / LOCAL mode.
Value:
0:
1:
Danger:
When changing the master control in operation, the drive can manifest undesirable behavior - e.g. it can accelerate
up to another setpoint.
r3986

Parameter count / Parameter No.

All objects
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the number of parameters for this drive unit.
The number comprises the device-specific and the drive-specific parameters.
Dependency:
Refer to: r0980, r0981, r0989
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Change master control for STW1.0 = 0
Change master control in operation
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
209

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents