Firmware Update Progress Display / Fw Update Progress; Firmware Download Component Number / Fw Downl Comp_No; Activate Firmware Download / Fw Download Act - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Value:
0:
1:
2:
Notice:
If this parameter is changed, it only becomes effective the next time that the drive system boots.
Note:
The firmware is automatically updated when the system boots. The boot can take several minutes.
After the update has been completed, it is necessary to carry out a new POWER ON (power-down/power-up) for the
components involved.
The firmware update procedure is displayed as follows:
Control Unit (LED RDY):
Flashes yellow with 0.5 Hz --> firmware is being updated.
Flashing yellow with 2 Hz --> POWER ON is required for the components involved.
Components involved:
Flashing red/green with 0.5 Hz --> firmware is being updated.
Flashing red/green with 2 Hz --> POWER ON of the components is required.
Only components from firmware version 2.5 support the red/green flashing at 2 Hz.
r7827

Firmware update progress display / FW update progress

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Displays the progress when updating the firmware of the DRIVE-CLiQ components.
p7828[0...1]

Firmware download component number / FW downl comp_no

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the component number for the required DRIVE-CLiQ component.
Index 0:
Component number of the DRIVE-CLiQ component for which a firmware download is to be made.
Index 1:
Component number of the DRIVE-CLiQ component for which the reference firmware version, saved in r7825 on the
memory card/device memory, is to be displayed.
Index:
[0] = Firmware download
[1] = Reference firmware version
Dependency:
Refer to: p0121, p0141, p0151, p7829
Note:
For p7828[0] = 399, the firmware for all of the existing components is downloaded.
The firmware download is started with p7829 = 1.
p7829

Activate firmware download / FW download act

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: -
Not for motor type: -
Min
-1
Description:
Activating the firmware download for the DRIVE-CLiQ components specified in p7828.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Deactivated
Upgrade and downgrade
Upgrade
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
399
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
999
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
297