2 Parameters
2.2 List of parameters
Note:
If the test command is issued in operation (i.e. in operating state o0.1 or o0.2), then the turn-off operation of the
SIMOREG CCP acts on the thyristor bridge that is presently enabled. This is independent of whether the turn-off
command is issued in torque direction I or II.
p51591[0...n]

Armature inductance reduction factor / L_armat red fact

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
10 [%]
Description:
Sets the reduction factor for the current-dependent armature inductance.
At 100% motor rated current (p50100), the armature inductance is lower than it is at armature current 0 by this factor.
Dependency:
Refer to: p50111
Note:
The parameter is set automatically during the "optimization run for pre-control and the current controller for the
armature converter" (p50051 = 25).
p51592[0...n]

Armature commutating inductance / Arm Lk

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [mH]
Description:
Sets the commutating inductance in the armature circuit.
p51594[0...n]
Interphase inductance in 12-pulse operation / L_intph 12-pulse
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [mH]
Description:
Sets the inductance of the interphase transformer in 12-pulse operation (two 6-pulse thyristor bridge circuits
connected in parallel).
Dependency:
Refer to: p51595
Note:
The parameter is set automatically during the "optimization run for pre-control and the current controller for the
armature converter" (p50051 = 25).
p51595[0...n]

Interphase inductance reduction factor / L_intph red fact

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
10 [%]
Description:
Sets the reduction factor for the current-dependent interphase inductance.
At 100% motor rated current (p50100), the interphase inductance is lower than it is at armature current 0 by this
factor.
Dependency:
Refer to: p51594
Note:
The parameter is set automatically during the "optimization run for pre-control and the current controller for the
armature converter" (p50051 = 25).
534
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1000.0 [mH]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1000000.0 [mH]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100 [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 6854
Unit selection: -
Expert list: 1
Factory setting
100 [%]
Access level: 3
Func. diagram: 6854
Unit selection: -
Expert list: 1
Factory setting
0.0 [mH]
Access level: 3
Func. diagram: 6854
Unit selection: -
Expert list: 1
Factory setting
0.0 [mH]
Access level: 2
Func. diagram: 6854
Unit selection: -
Expert list: 1
Factory setting
100 [%]