Siemens SINAMICS DCM List Manual page 52

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r0108
Drive objects function module / DO fct_mod
DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Closed-loop control
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the activated function module for the particular drive object.
Bit field:
Bit
16
18
31
Note:
A "function module" is a functional expansion of a drive object that can be activated when commissioning.
r0108
Drive objects function module / DO fct_mod
TM150, TM15DI_DO,
Can be changed: -
TM31
Data type: Unsigned32
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Displays the activated function module for the particular drive object.
Bit field:
Bit
18
31
Note:
A "function module" is a functional expansion of a drive object that can be activated when commissioning.
r0110[0...2]
Basic sampling times / t_basis
CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Closed-loop control
Not for motor type: -
Min
0.00 [µs]
Description:
Displays the basic sampling times.
The sampling times are set using p0112 and p0115. The values for the basic sampling times are determined as a
result of these settings.
Index:
[0] = Basic sampling time 0
[1] = Basic sampling time 1
[2] = Basic sampling time 2
r0111
Basic sampling time selection / t_basis sel
CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Integer16
CU_DC_S, DC_CTRL,
P-Group: Closed-loop control
DC_CTRL_R,
Not for motor type: -
DC_CTRL_R_S,
DC_CTRL_S
Min
0
Description:
Displays the selected basic sampling time for this drive object.
Dependency:
Refer to: r0110
52
Signal name
Techn controller / Tech_ctrl
Free function blocks / FBLOCKS
PROFINET CBE20 / PROFINET CBE20
Signal name
Free function blocks / FBLOCKS
PROFINET CBE20 / PROFINET CBE20
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Activated
Activated
Activated
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Activated
Activated
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000.00 [µs]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Not activated
Not activated
Not activated
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Not activated
Not activated
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [µs]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS DCM