Cbe2X Default Gateway Of Station Active / Cbe2X Def Gw Act; Cbe2X Subnet Mask Of Station Active / Cbe2X Sub Mask Act; Cbe2X Dhcp Mode Active / Cbe2X Dhcp Act; Cbe2X Mac Address Of Station / Cbe2X Mac Addr - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r8952[0...3]

CBE2x Default Gateway of Station active / CBE2x def GW act

CU_DC (PROFINET
Can be changed: -
CBE20), CU_DC_R
Data type: Unsigned8
(PROFINET CBE20),
P-Group: -
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
0
Description:
Displays the active standard gateway for the Communication Board Ethernet 20/25 (CBE20/CBE25).
r8953[0...3]

CBE2x Subnet Mask of Station active / CBE2x Sub Mask act

CU_DC (PROFINET
Can be changed: -
CBE20), CU_DC_R
Data type: Unsigned8
(PROFINET CBE20),
P-Group: -
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
0
Description:
Displays the active subnet mask for the Communication Board Ethernet 20/25 (CBE20/CBE25).
r8954

CBE2x DHCP Mode active / CBE2x DHCP act

CU_DC (PROFINET
Can be changed: -
CBE20), CU_DC_R
Data type: Unsigned8
(PROFINET CBE20),
P-Group: -
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
0
Description:
Displays the active DHCP mode for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Notice:
When the DHCP mode is active (parameter value greater than 0), PROFINET communication via this interface is no
longer possible! However, the interface can be used by the STARTER/SCOUT commissioning tool.
Note:
If value = 0:
DHCP deactivated.
If value = 2:
DHCP activated. The MAC address of this interface is used for client identification.
If value = 3:
DHCP activated. The station name of this interface is used for client identification.
r8955[0...5]

CBE2x MAC Address of Station / CBE2x MAC Addr

CU_DC (PROFINET
Can be changed: -
CBE20), CU_DC_R
Data type: Unsigned8
(PROFINET CBE20),
P-Group: -
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
0000 hex
Description:
Displays the MAC address for the Communication Board Ethernet 20/25 (CBE20/CBE25).
r8959
CBE2x DAP ID / CBE2x DAP ID
CU_DC (PROFINET
Can be changed: -
CBE20), CU_DC_R
Data type: Unsigned32
(PROFINET CBE20),
P-Group: -
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
0000 hex
Description:
Displays the DAP ID for PROFINET via the Communication Board Ethernet 20/25 (CBE20/CBE25).
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
00FF hex
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
FFFF FFFF hex
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
347