Bi: Jog Setpoint Signal Source For Connector Selection; Ci: Signal Source For Jog Setpoint / Jog Set Sig S; Jog Setpoint Bypass Ramp-Function Generator; Ci: Jog Signal Source For Default Setpoint / Jog Def Set Sig S - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p50435[0...7]
BI: Jog setpoint signal source for connector selection / Jog set conn sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the selection of the connectors (p50436[0 to 7]).
p50436[0...7]

CI: Signal source for jog setpoint / Jog set sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal sources for generating the jog setpoint (CO: r52202).
p50437[0...7]
Jog setpoint bypass ramp-function generator / Jog set bypass RFG
DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to enable or disable the impact of the individual jog setpoints when generating signal r53170.11, "Bypass
ramp-function generator".
Value:
0:
1:
Note:
[0] = Enable bypassing of ramp-function generator at jog setpoint 0
...
[7] = Enable bypassing of ramp-function generator at jog setpoint 7
p50438[0...n]

CI: Jog signal source for default setpoint / Jog def set sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the default setpoint when jog is not selected.
p50440[0...7]
BI: Creep setpoint signal source for connector selection / Cr set sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the selection of the connectors (p50441[0 to 7]) for the creep setpoint.
Dependency:
Refer to: p50441
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Do not bypass
Bypass
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 3125
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3125
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3125
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3125
Unit selection: -
Expert list: 1
Factory setting
52208[0]
Access level: 2
Func. diagram: 3130
Unit selection: -
Expert list: 1
Factory setting
0
459

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents