p50108[0...n]
Speed-dependent current limitation maximum operating speed n3 / I_lim n_dep n3
DC_CTRL
Can be changed: C2(1), U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
1 [1 rpm]
Description:
Sets the maximum operating speed n3 for "speed-dependent current limitation".
Dependency:
Refer to: p50104, p50105, p50106, p50107, p50109
Note:
In this parameter, the following maximum speed must be set dependent upon the setting of the signal source for the
speed actual value (p50083):
- p50083 = 1 (analog tachometer): Speed prevailing at a tachometer voltage according to p50741
- p50083 = 2 (incremental encoder TTL/HTL): Same value as maximum speed according to p50143
- p50083 = 3 (operation without tachometer): Speed prevailing at an EMF according to p50115.
p50109[0...n]

Speed-dependent current limitation activation / I_lim n_dep act

DC_CTRL
Can be changed: C2(1), U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets activation/de-activation of the "speed-dependent current limitation" function.
Value:
0:
1:
p50110[0...n]

Armature circuit resistance / Ra

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.000 [ohm]
Description:
Sets the armature circuit resistance.
Note:
The parameter is set automatically during the optimization run for pre-control and the current controller for the
armature converter (p50051 = 25).
p50111[0...n]

Armature circuit inductance / La

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.000 [mH]
Description:
Sets the armature circuit inductance.
Note:
The parameter is set automatically during the optimization run for pre-control and the current controller for the
armature converter (p50051 = 25).
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Deactivated
Activated
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000 [1 rpm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
4000.000 [ohm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1000000.000 [mH]
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: 8040
Unit selection: -
Expert list: 1
Factory setting
5000 [1 rpm]
Access level: 1
Func. diagram: 8040
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 6852, 6855,
6900, 6902
Unit selection: -
Expert list: 1
Factory setting
0.000 [ohm]
Access level: 3
Func. diagram: 6852, 6854,
6902
Unit selection: -
Expert list: 1
Factory setting
0.000 [mH]