2 Parameters
2.2 List of parameters
p9942
DRIVE-CLiQ detailed diagnostics select individual connection / DQ detail conn
CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the component, whose feeder cable is monitored for data transfer errors.
The feeder cable is the DRIVE-CLiQ cable that is connected to a component in the direction of the Control Unit.
Errors that have occurred in the selected time interval (p9939) can be read-out from r9943.
Dependency:
Refer to: r9936, p9938, p9939, r9943
r9943
DRIVE-CLiQ detailed diagn. individual connection error counter / DQ det err counter
CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Integer32
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the connection errors of the individual connection that have occurred within the time interval (p9939).
The detailed diagnostics for the individual connection is activated via p9938 > 0 and is selected via p9942.
Dependency:
Refer to: r9936, p9938, p9939, p9942
r9975[0...7]

System utilization measured / Sys util meas

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Displays the measured system utilization.
The higher the value displayed, the higher the system utilization.
Index:
[0] = Computing time utilization (min)
[1] = Computing time utilization (averaged)
[2] = Computing time utilization (max)
[3] = Largest total utilization (min)
[4] = Largest total utilization (averaged)
[5] = Largest total utilization (max)
[6] = Reserved
[7] = Reserved
Dependency:
Refer to: r9976, r9979, r9980, r9981
Note:
Re index 3 ... 5:
The total utilizations are determined using all sampling times used. The largest total utilizations are mapped here.
The sampling time with the largest total utilization is displayed in r9979.
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
368
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
199
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]