Co/Bo: Xist1_Erw Status / Xist1_Erw Stat; Bi: Xist1_Erw Reset Signal Source / Xist1_Erw Ress_Src; Sensor Module Filter Bandwidth / Sm Filt_Bandw - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r4654.0...8

CO/BO: XIST1_ERW status / XIST1_ERW stat

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Display and binector output to reset XIST1_ERW.
Bit field:
Bit
00
08
Dependency:
Refer to: p4652, r4653, p4655
Note:
The reset of XIST1_ERW is initiated via binector input p4655.
Binector output r4654 is reset with a 0 signal from binector input p4655.
p4655[0...2]

BI: XIST1_ERW reset signal source / XIST1_ERW resS_src

DC_CTRL,
Can be changed: T
DC_CTRL_R,
Data type: Unsigned32 / Binary
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Sets the signal source to reset XIST1_ERW (CO: r4653).
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = -
Dependency:
Refer to: p4652, r4653, r4654
Note:
The reset of XIST1_ERW depends on the selected mode (p4652).
p4660[0...2]

Sensor Module filter bandwidth / SM Filt_bandw

DC_CTRL,
Can be changed: C2(4)
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
0.00 [kHz]
Description:
Sets the filter bandwidth for Sensor Module SMx10 (resolver) and SMx20 (sin/cos).
The value set on the Sensor Module is displayed in r4661.
The Sensor Module hardware only supports the following values:
- 0: The Sensor Module's default is used.
- 50 kHz
- 170 kHz
- 500 kHz
- Unlimited: Only the bandwidth of the operational amplifier is effective.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: r4661
Note:
A value of zero is displayed if an encoder is not present.
252
Signal name
Encoder 1 XIST1_ERW reset
Encoder 2 XIST1_ERW reset
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
High
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
20000.00 [kHz]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: 4750
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Access level: 3
Func. diagram: 4750
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [kHz]
SINAMICS DCM
FP
-
-

Hide quick links:

Advertisement

Table of Contents
loading