Sensor Module Properties Extended / Sm Prop Ext; Encoder Serial Number Part 1 / Enc Ser_No 1 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r0459[0...2]

Sensor Module properties extended / SM prop ext

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the extended properties supported by the Sensor Module.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = -
Bit field:
Bit
00
01
02
04
05
06
07
09
10
11
12
13
14
15
16
17
24
25
26
28
29
31
Dependency:
Refer to: p0437
Note:
A value of zero is displayed if an encoder is not present.
Re bit 09:
Parameter p0426 or p0439 has been modified. These functions are not supported by the connected Sensor Module.
r0460[0...2]

Encoder serial number part 1 / Enc ser_no 1

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the actual serial number part 1 of the appropriate encoder.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = -
Dependency:
Refer to: p0441, p0442, p0443, p0444, p0445, r0461, r0462, r0463, r0464
82
Signal name
Data logger
Zero mark edge detection
Correction position actual value XIST1
Edge evaluation bit 0
Edge evaluation bit 1
Freeze the speed actual value for dn/dt
errors
Accumulate uncorrected encoder pulses
Function p0426, p0439 supported
Pulse/direction interface
Fault handling after PROFIdrive
Activate additional messages
Absolute position for incremental encoder
supported
Spindle functionality
Additional temperature sensor available
Internal encoder temperature available
Extended multiturn resolution
Multiturn via battery
Deselect monitoring multiturn
representation in Gx_XIST2
Track monitoring de-selection
EnDat linear encoder monitoring
incremental/absolute
EnDat encoder initialization with high
accuracy
Analog unipolar track monitoring
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS DCM
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents