p50775

CUD digital output 0 delay time / CUD DO 0 t_del

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the delay time for digital output 0 (X177.19) on the CUD.
Note:
The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
p50776

CUD digital output 1 delay time / CUD DO 1 t_del

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the delay time for digital output 1 (X177.20) on the CUD.
Note:
The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
p50777

CUD digital output 2 delay time / CUD DO 2 t_del

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the delay time for digital output 2 (X177.21) on the CUD.
Note:
The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
p50778

CUD digital output 3 delay time / CUD DO 3 t_del

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the delay time for digital output 3 (X177.22) on the CUD.
Note:
The level at the digital output can only change if the changed internal level remains constant for longer than the set
delay time.
p50780[0...3]
CUD digital inputs/outputs inversion / CUD DI/DO inv
DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to invert the signals at the CUD's digital outputs.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 2055
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 2055
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 2055
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 2055
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 2060, 2065
Unit selection: -
Expert list: 1
Factory setting
0