Field Bus Int Uss Pzd No. / Field Bus Uss Pzd; Field Bus Int Uss Pkw No. / Field Bus Uss Pkw; Field Bus Int Error Statistics / Field Bus Error; Field Bus Int Protocol Selection / Field Bus Protocol - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p2022

Field bus int USS PZD no. / Field bus USS PZD

CU_DC, CU_DC_R,
Can be changed: T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the number of 16-bit words in the PZD part of the USS telegram for the field bus interface.
Dependency:
Refer to: p2030
Note:
The parameter is not influenced by setting the factory setting.
p2023

Field bus int USS PKW no. / Field bus USS PKW

CU_DC, CU_DC_R,
Can be changed: T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the number of 16-bit words in the PKW part of the USS telegram for the field bus interface.
Value:
0:
3:
4:
127:
Dependency:
Refer to: p2030
Note:
The parameter is not influenced by setting the factory setting.
r2029[0...7]

Field bus int error statistics / Field bus error

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
-
Description:
Displays the receive errors on the field bus interface (USS).
Index:
[0] = Number of error-free telegrams
[1] = Number of rejected telegrams
[2] = Number of framing errors
[3] = Number of overrun errors
[4] = Number of parity errors
[5] = Number of starting character errors
[6] = Number of checksum errors
[7] = Number of length errors
p2030

Field bus int protocol selection / Field bus protocol

CU_DC, CU_DC_R,
Can be changed: T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the communication protocol for the field bus interface.
Value:
0:
1:
3:
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
PKW 0 words
PKW 3 words
PKW 4 words
PKW variable
No protocol
USS
PROFIBUS
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
16
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
127
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 9310
Unit selection: -
Expert list: 1
Factory setting
2
Access level: 2
Func. diagram: 9310
Unit selection: -
Expert list: 1
Factory setting
127
Access level: 3
Func. diagram: 9310
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
3
127

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents