The message is triggered when the threshold is undershot.
Once the value rises above the threshold plus the hysteresis, the message is withdrawn.
Dependency:
Refer to: p50370, p50593, r53025
Note:
The "Speed less than minimum speed reached" message is available as follows:
- r53025.6 (not inverted)
- r53025.7 (inverted)
p50372[0...n]
Messages speed positive hysteresis / Msg n > 0 hyst
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the hysteresis for the "Speed positive" message.
This parameter acts on the "Speed setpoint positive" message as well as on the "Speed actual value positive"
message.
Dependency:
Refer to: p50594, p50598, r53025
Note:
The "Speed positive" message is available as follows:
Setpoint:
- r53025.8 (not inverted)
- r53025.9 (inverted)
Actual value:
- r53025.12 (not inverted)
- r53025.13 (inverted)
p50373[0...n]

Messages for reference speed threshold / Ref_speed thresh

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the threshold for the "Reference speed reached" message.
Dependency:
Refer to: p50374, p50375, p50592, r53025
Note:
The "Reference speed reached" message is available as follows:
- r53025.4 (not inverted)
- r53025.5 (inverted)
p50374[0...n]

Messages for reference speed hysteresis / Ref_speed hyst

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the hysteresis for the "Reference speed reached" message.
The message is triggered when the threshold is overshot.
Once the value falls below the threshold minus the hysteresis, the message is withdrawn.
Dependency:
Refer to: p50373, p50375, p50592, r53025
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
10.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8025
Unit selection: -
Expert list: 1
Factory setting
0.10 [%]
Access level: 2
Func. diagram: 8020
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 8020
Unit selection: -
Expert list: 1
Factory setting
3.00 [%]