Siemens SINAMICS DCM List Manual page 312

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p8550
AOP LOCAL/REMOTE / AOP LOCAL/REMOTE
CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Setting for saving the actual configuration of the Advanced Operator Panel (AOP).
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
14
15
r8570[0...39]
Macro drive object / Macro DO
All objects
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the macro file saved in the appropriate directory on the memory card/device memory.
Dependency:
Refer to: p0015
Note:
For a value = 9999999, the following applies: The read operation is still running.
r8571[0...39]
Macro Binector Input (BI) / Macro BI
DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: -
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency:
Refer to: p0700
Note:
For a value = 9999999, the following applies: The read operation is still running.
r8572[0...39]
Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: -
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency:
Refer to: p1000
Note:
For a value = 9999999, the following applies: The read operation is still running.
312
Signal name
LOCAL save
Start in LOCAL
Change in oper
OFF acts like OFF1
OFF acts like OFF2
OFF acts like OFF3
Reserved
CW/CCW active
Jog active
Save speed setpoint
Inhibit operation
Inhibit parameterization
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 1001 bin
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
SINAMICS DCM
FP
-
-
-
-
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents