Ci: If1 Profidrive Pzd Send Word / If1 Pzd Send Word - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p2051[0...24]

CI: IF1 PROFIdrive PZD send word / IF1 PZD send word

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32 / Integer16
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
-
Description:
Selects the PZD (actual values) with word format to be sent to the fieldbus controller.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
[16] = PZD 17
[17] = PZD 18
[18] = PZD 19
[19] = PZD 20
[20] = PZD 21
[21] = PZD 22
[22] = PZD 23
[23] = PZD 24
[24] = PZD 25
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
IF1: Interface 1
p2051[0...63]
CI: IF1 PROFIdrive PZD send word / IF1 PZD send word
DC_CTRL,
Can be changed: U, T
DC_CTRL_R,
Data type: Unsigned32 / Integer16
DC_CTRL_R_S,
DC_CTRL_S
P-Group: Communications
Not for motor type: -
Min
-
Description:
Selects the PZD (actual values) with word format to be sent to the fieldbus controller.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: 4000H
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: 4000H
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2450, 2483
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2450, 2470,
2483
Unit selection: -
Expert list: 1
Factory setting
0
133

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents