4 Faults and alarms
4.1 Overview of faults and alarms
4.1.2

Explanation of the list of faults and alarms

The data in the following example have been chosen at random. The information listed below
is the maximum amount of information that a description can contain. Some of the information
is optional.
The "List of faults and alarms" (Page 870) has the following layout:
- - - - - - - - - - - - Start of example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axxxxx (F, N)
Fault location (optional): Name
Message value:
Component number: %1, fault cause: %2
Message class:
Text of the message class (number according to PROFIdrive)
Drive object:
List of objects.
Reaction:
NONE
Acknowledgment:
NONE
Cause:
Description of possible causes.
Fault value (r0949, interpret format): or alarm value (r2124, interpret format): (optional)
Information about fault or alarm values (optional).
Remedy:
Description of possible remedies.
Reaction to F:
NONE (OFF1, OFF2, OFF3)
Acknowledgment for F: IMMEDIATELY (POWER ON)
Reaction to N:
NONE
Acknowledgment for N: NONE
- - - - - - - - - - - - End of example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axxxxx
Alarm xxxxx
Axxxxx (F, N)
Alarm xxxxx (message type can be changed in F or N)
Fxxxxx
Fault xxxxx
Fxxxxx (A, N)
Fault xxxxx (message type can be changed in A or N)
Nxxxxx
No message
Nxxxxx (A)
No message (message type can be changed in A)
A message comprises a letter followed by the relevant number.
The meaning of the letters is as follows:
• A means "Alarm"
• F means "Fault"
• N means "No message" or "Internal message" (or "No report")
The optional brackets indicate whether the type specified for this message can be changed
and which message types can be adjusted via parameters (p2118, p2119).
Information about reaction and acknowledgment is specified independently for a message with
adjustable message type (e.g. reaction to F, acknowledgment for F).
862
List Manual (LH8), 02/2015, 6RX1800-0ED76
SINAMICS DCM