Co: Optimization Run Output 1 / Opt Run Outp 1; Co: Optimization Run Output 2 / Opt Run Outp 2; Co: Optimization Run Output 3 / Opt Run Outp 3; Co: Optimization Run Output 4 / Opt Run Outp 4 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r52901

CO: Optimization run output 1 / Opt run outp 1

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of output 1 during the optimization run.
r52902

CO: Optimization run output 2 / Opt run outp 2

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of output 2 during the optimization run.
r52903

CO: Optimization run output 3 / Opt run outp 3

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of output 3 during the optimization run.
r52904

CO: Optimization run output 4 / Opt run outp 4

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of output 4 during the optimization run.
r52921[0...4]
CO: Measurement results ASIC 1 raw values / Meas res ASIC1 raw
DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output for the raw values from the measurements of Power Stack ASIC 1.
For devices with 480 V:
- 0 corresponds to -825.0 V
- 32767 corresponds to 0 V
- 65535 corresponds to +825.0 V
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 2660
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 2660
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 2660
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 2660
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 4
Func. diagram: 8054
Unit selection: -
Expert list: 1
Factory setting
-
623

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents