p50561[0...n]

Speed controller adaptation droop x coordinate 2 / Adapt droop x2

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the x coordinate for pair of values 2 for adaptation of the droop.
Notice:
The following condition applies for x coordinate 1/2:
p50558 < p50561
Note:
The adaptation of the droop is defined using 2 pairs of values.
Pair of values 1:
p50558/p50552 (x/y coordinate)
Pair of values 2:
p50561/p50227 (x/y coordinate)
p50562[0...n]

Speed controller droop positive limiting / Droop pos lim

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets positive limiting for the droop on the speed controller.
Dependency:
Refer to: p50563
p50563[0...n]

Speed controller droop negative limiting / Droop neg lim

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-200.00 [%]
Description:
Sets negative limiting for the droop on the speed controller.
Dependency:
Refer to: p50562
p50565
Speed controller optimization frequency response plot base speed / f_plot n_base
DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
1.0 [%]
Description:
Sets the base speed for the frequency response plot for the optimization run "Speed control optimization for drives
that are capable of oscillation" (p50051 = 29).
Dependency:
Refer to: p50566, p50567
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
0.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
30.0 [%]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6805
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 2
Func. diagram: 6805
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 6805
Unit selection: -
Expert list: 1
Factory setting
-100.00 [%]
Access level: 2
Func. diagram: 2660
Unit selection: -
Expert list: 1
Factory setting
20.0 [%]
477