Co: Setpoint Processing Setpoint Before Reduction; Co: Setpoint Processing Main Setpoint Upper Limit Effective; Co: Setpoint Processing Main Setpoint Lower Limit Effective; Co: Setpoint Processing Main Setpoint Before Limiting - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r52195
CO: Setpoint processing setpoint before reduction / Set before reduc
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the sum "main setpoint (limited) + additional setpoint" before setpoint reduction.
Dependency:
Refer to: p51607, p51608, r52194
Note:
Setpoint reduction is set via p51608 and activated/de-activated via binector input p51607.
r52196
CO: Setpoint processing main setpoint upper limit effective / M set up lim eff
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the effective upper limit in the case of main setpoint limiting.
r52197
CO: Setpoint processing main setpoint lower limit effective / M set low lim eff
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the effective lower limit in the case of main setpoint limiting.
r52198
CO: Setpoint processing main setpoint before limiting / M_setp bef lim
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the main setpoint before setpoint limiting.
r52201
CO: Creep setpoint output / Creep set outp
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the sum of all creep setpoints (p504441[0 to 7]).
Dependency:
Refer to: p50440, p50441
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 3130
Unit selection: -
Expert list: 1
Factory setting
- [%]
583

Hide quick links:

Advertisement

Table of Contents