Measuring Gear Configuration / Meas Gear Config; Measuring Gear Absolute Encoder Rotary Revolutions Virtual - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p0411[0...n]

Measuring gear configuration / Meas gear config

DC_CTRL,
Can be changed: C2(4)
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Sets the configuration for position tracking of a measuring gear.
Bit field:
Bit
00
01
02
03
Notice:
For p0411.3 = 1 the following applies:
If position tracking is activated for incremental encoders, only the position actual value is stored. Axis or encoder
motion is not detected when de-activated! Any tolerance window entered in p0413 has no effect.
Note:
For the following events, the non-volatile, saved position values are automatically reset:
- when an encoder replacement has been identified.
- when changing the configuration of the Encoder Data Set (EDS).
p0412[0...n]
Measuring gear absolute encoder rotary revolutions virtual / Abs rot rev
DC_CTRL,
Can be changed: C2(4)
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Sets the number of rotations that can be resolved for a rotary encoder with activated position tracking of the
measuring gear.
Dependency:
This parameter is only of significance for an absolute encoder (p0404.1 = 1) with activated position tracking (p0411.0
= 1) and for an incremental encoder with activated position tracking (p0411.3 = 1).
Note:
The resolution that is set must be able to be represented using r0483.
For rotary axes/modulo axes, the following applies:
p0411.0 = 1:
This parameter is pre-set with p0421 and can be changed.
p0411.3 = 1:
The parameter value is pre-set to the highest possible value. The highest possible value depends on the pulse
number (p0408) and the fine resolution (p0419).
For linear axes, the following applies:
p0411.0 = 1:
This parameter is pre-assigned with p0421, expanded by 6 bits for multiturn information (maximum number of
overflows) and cannot be changed.
p0411.3 = 1:
The parameter value is pre-set to the highest possible value. The highest possible value depends on the pulse
number (p0408) and the fine resolution (p0419).
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
Measuring gear activate position tracking
Axis type
Measuring gear reset position
Meas. gearbox, activate pos. tracking for
incremental encoders
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Linear axis
Yes
Yes
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
4194303
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: 4704
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
No
Rotary axis
No
No
Access level: 1
Func. diagram: 4704
Unit selection: -
Expert list: 1
Factory setting
0
FP
-
-
-
-
67

Hide quick links:

Advertisement

Table of Contents
loading