Co/Bo: Field Current Messages / If Messages; Co/Bo: Cud Analog Inputs Wire Break Message; Co/Bo: Sequence Control Line Contactor Control; Co/Bo: Line Contactor State / Line Cont State - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r53026.0...1

CO/BO: Field current messages / If messages

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Control word for field current thresholds.
Bit field:
Bit
00
01
r53030.0...1
CO/BO: CUD analog inputs wire break message / CUD AI wire brk
DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output for the "Wire break" message in the case of the CUD analog inputs.
Bit field:
Bit
00
01
Dependency:
Refer to: F60046, F60047
r53081.0...1
CO/BO: Sequence control line contactor control / Ctrl line cont
DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output for the line contactor control.
Bit field:
Bit
00
01
r53082.0

CO/BO: Line contactor state / Line cont state

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the status of the line contactor control.
Bit field:
Bit
00
Dependency:
Refer to: p51619
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
Field current less than minimum field
current threshold
Field current actual value less than field
current setpoint x
Signal name
AI "Main setpoint" wire-break monitoring
responded
AI 1 (X177.27/28) Wire-break monitoring
responded
Signal name
Line contactor
Line contactor inverted
Signal name
Line contactor ON
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
ON
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8025
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
Access level: 2
Func. diagram: 2075, 2080
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
Access level: 2
Func. diagram: 2651
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF
OFF
Access level: 2
Func. diagram: 2070
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
FP
-
-
FP
2075
2080
FP
2651
2651
FP
2070
633

Hide quick links:

Advertisement

Table of Contents