2 Parameters
2.2 List of parameters
p50105[0...n]
Speed-dependent current limitation armature current I1 / I_lim n_dep I1
DC_CTRL
Can be changed: C2(1), U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.1 [A]
Description:
Sets armature current I1 according to the motor's nameplate for "speed-dependent current limitation".
The characteristic for "speed-dependent current limitation" is defined by 2 pairs of values (p50104/p50105,
p50106/p50107).
This parameter sets armature current I1 for the first pair of values (p50104/p50105).
Dependency:
Refer to: p50104, p50106, p50107, p50108, p50109
Note:
The following condition applies:
p50105 >= p50107 (I1 >= I2)
p50106[0...n]

Speed-dependent current limitation speed n2 / I_lim n_dep n2

DC_CTRL
Can be changed: C2(1), U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
1 [1 rpm]
Description:
Sets speed n2 according to the motor's nameplate for "speed-dependent current limitation".
The characteristic for "speed-dependent current limitation" is defined by 2 pairs of values (p50104/p50105,
p50106/p50107).
This parameter sets speed n2 for the second pair of values (p50106/p50107).
Dependency:
Refer to: p50104, p50105, p50107, p50108, p50109
Note:
The following condition applies:
p50104 <= p50106 (n1 <= n2)
p50107[0...n]
Speed-dependent current limitation armature current I2 / I_lim n_dep I2
DC_CTRL
Can be changed: C2(1), U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.1 [A]
Description:
Sets armature current I2 according to the motor's nameplate for "speed-dependent current limitation".
The characteristic for "speed-dependent current limitation" is defined by 2 pairs of values (p50104/p50105,
p50106/p50107).
This parameter sets armature current I2 for the second pair of values (p50106/p50107).
Dependency:
Refer to: p50104, p50105, p50106, p50108, p50109
Note:
The following condition applies:
p50105 >= p50107 (I1 >= I2)
400
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
20000.0 [A]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000 [1 rpm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
20000.0 [A]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 8040
Unit selection: -
Expert list: 1
Factory setting
0.1 [A]
Access level: 1
Func. diagram: 8040
Unit selection: -
Expert list: 1
Factory setting
5000 [1 rpm]
Access level: 1
Func. diagram: 8040
Unit selection: -
Expert list: 1
Factory setting
0.1 [A]