Co: Cl-Loop Arm Curr Control Curr Controller Setpoint; Co: Curr Limitation Arm Curr Setpoint Before Red Gearbox Stressing; Co: Closed-Loop Armature Current Control Pre-Control Output; Co: Emf Actual Value Armature Current Pre-Control - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r52119
CO: Cl-loop arm curr control curr controller setpoint / Ia ctr I_set
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the current controller setpoint prior to absolute value generation for closed-loop
armature current control.
r52120
CO: Curr limitation arm curr setpoint before red gearbox stressing / Ia_set bef gear
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the current controller setpoint before reduced gearbox stressing.
r52121
CO: Closed-loop armature current control pre-control output / Ia ctr prec outp
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the armature current pre-control output.
r52122
CO: EMF actual value armature current pre-control / EMF act prec
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the EMF actual value for armature current pre-control.
Note:
100% corresponds to p50078[0] * (3 * sqrt(2)) / Pi.
r52123
CO: EMF actual value signed / EMF act sign
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the signed unsmoothed EMF actual value.
Note:
100% corresponds to p50078[0] * (3 * sqrt(2)) / Pi.
570
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 6855
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6845
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6855
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6852, 6855
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6852, 6902
Unit selection: -
Expert list: 1
Factory setting
- [%]
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading