Co: Speed Limiting Controller Curr Controller Setp Before Limitation; Co: Current Limitation Default For Torque Direction Ii; Co: Speed Limiting Controller Upper Torque Limit Effective; Co: Speed Limiting Controller Lower Torque Limit Effective - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r52134
CO: Speed limiting controller curr controller setp before limitation / Ia set bef lim
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the current controller setpoint before current limitation.
r52135[0...6]
CO: Current limitation default for torque direction II / Ia lim def t d II
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the variable torque limiting defaults in torque direction II.
Dependency:
Refer to: p50603, p50604
Note:
Connector output r52135[0 to 6] is the inverse of p50603[0 to 6] and interconnected by default via connector input
p50604[0 to 6].
r52136
CO: Speed limiting controller upper torque limit effective / n_lim t lim up max
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the effective upper torque limit (maximum value) on the speed limiting controller.
Dependency:
Refer to: r52137
r52137
CO: Speed limiting controller lower torque limit effective / n_lim t lim l min
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the effective lower torque limit (minimum value) on the speed limiting controller.
Dependency:
Refer to: r52136
r52138[0...4]
CO: Torque limiting negative default / Tqe lim neg def
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the defaults for variable negative torque limiting.
Dependency:
Refer to: p50606
Note:
Connector output r52138[0 to 4] is the inverse of p50605[0 to 4]; it is interconnected by default via connector input
p50606[0 to 4].
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: 6835
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6840
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6835
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6835
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6825
Unit selection: -
Expert list: 1
Factory setting
- [%]
573