Ci: Torque Limiting Signal Source For Positive Torque Limit; Ci: Torque Limiting Signal Source For Negative Torque Limit; Ci: Torque Limiting Signal Source For Master Drive T_Set; Ci: Auto-Reversing Stage Signal Source For Torque Direction Setpoint - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

About [5]:
Selects which parameter is injected as the variable current limit in torque direction II.
Scaling: +100% corresponding to r50072[1].
About [6]:
Selects which parameter is injected as the current limit in torque direction II for quick stop or shutdown.
Scaling: +100% corresponding to r50072[1].
p50605[0...4]
CI: Torque limiting signal source for positive torque limit / T lim pos sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the variable positive torque limit.
Note:
Scaling:
[0 to 3] = 100% of the parameter value corresponds to the positive system torque limit according to Ia = p50171.
[4] = 100% of the parameter value corresponds to the positive torque limit according to Ia =r50072[1].
p50606[0...4]
CI: Torque limiting signal source for negative torque limit / T lim neg sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the variable negative torque limit.
Note:
Scaling:
[0 to 3] = 100% of the parameter value corresponds to the negative system torque limit according to Ia = p50171.
[4] = 100% of the parameter value corresponds to the negative torque limit according to Ia =r50072[1].
p50607[0...n]
CI: Torque limiting signal source for master drive t_set / Mst tq set sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the master drive's torque setpoint.
p50608
CI: Auto-reversing stage signal source for torque direction setpoint / Tqe dir set sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the torque direction setpoint for the auto-reversing stage.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 6825
Unit selection: -
Expert list: 1
Factory setting
52002[0]
Access level: 3
Func. diagram: 6825
Unit selection: -
Expert list: 1
Factory setting
[0] 52138[0]
[1] 52138[1]
[2] 52138[2]
[3] 52138[3]
[4] 52138[4]
Access level: 3
Func. diagram: 6830
Unit selection: -
Expert list: 1
Factory setting
52148[0]
Access level: 3
Func. diagram: 6860
Unit selection: -
Expert list: 1
Factory setting
52119[0]
485