Ci: Field Reversal Speed Actual Value Signal Source; Ci: Messages For Set/Act Val Dev 1 Signal Source For Speed Setpoint; Ci: Messages For Set/Act Val Dev 1 Signal Source For Speed Act Val; Ci: Messages For Ref Speed Signal Source For Speed Actual Value - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Dependency:
Refer to: p50092, p50580, p50583, r53195
p50583[0...n]
CI: Field reversal speed actual value signal source / FldRev n_act sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed actual value when reversing the field.
Dependency:
Refer to: p50092, p50580, p50581, r53195
p50590

CI: Messages for set/act val dev 1 signal source for speed setpoint /

Msg dev1 set sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed setpoint for the "Setpoint/actual value deviation 1" message.
Dependency:
Refer to: p50591, r53025
Refer to: F60031
p50591
CI: Messages for set/act val dev 1 signal source for speed act val / Msg dev1 act sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed actual value for the "Setpoint/actual value deviation 1" message.
Dependency:
Refer to: p50590, r53025
Refer to: F60031
p50592
CI: Messages for ref speed signal source for speed actual value / Msg ref act sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed actual value for the "Reference speed reached" message.
Dependency:
Refer to: r53025
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6920
Unit selection: -
Expert list: 1
Factory setting
52167[0]
Access level: 2
Func. diagram: 8020
Unit selection: -
Expert list: 1
Factory setting
52165[0]
Access level: 2
Func. diagram: 8020
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 8020
Unit selection: -
Expert list: 1
Factory setting
52167[0]
481