2 Parameters
2.2 List of parameters
p1055[0...n]

BI: Jog bit 0 / Jog bit 0

DC_CTRL,
Can be changed: T
DC_CTRL_R,
Data type: Unsigned32 / Binary
DC_CTRL_R_S,
P-Group: Setpoints
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Sets the signal source for jog 1.
Recommendation:
When the setting for this binector input is changed, the motor can only be switched on by means of an appropriate
signal change of the source.
Dependency:
Refer to: p0840
Notice:
The drive is enabled for jogging using BI: p1055 or BI: p1056.
The command "ON/OFF1" can be issued using BI: p0840 or using BI: p1055/p1056.
Only the signal source that was used to power up can also be used to power down again.
p1056[0...n]

BI: Jog bit 1 / Jog bit 1

DC_CTRL,
Can be changed: T
DC_CTRL_R,
Data type: Unsigned32 / Binary
DC_CTRL_R_S,
P-Group: Setpoints
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Sets the signal source for jog 2.
Recommendation:
When the setting for this binector input is changed, the motor can only be switched on by means of an appropriate
signal change of the source.
Dependency:
Refer to: p0840
Notice:
The drive is enabled for jogging using BI: p1055 or BI: p1056.
The command "ON/OFF1" can be issued using BI: p0840 or using BI: p1055/p1056.
Only the signal source that was used to power up can also be used to power down again.
p1070[0...n]

CI: Main setpoint / Main setpoint

DC_CTRL,
Can be changed: T
DC_CTRL_R,
Data type: Unsigned32 / FloatingPoint32
DC_CTRL_R_S,
P-Group: Setpoints
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Sets the signal source for the main setpoint.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1113[0...n]

BI: Setpoint inversion / Setp inv

DC_CTRL,
Can be changed: T
DC_CTRL_R,
Data type: Unsigned32 / Binary
DC_CTRL_R_S,
P-Group: Setpoints
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Sets the signal source to invert the setpoint.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
120
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: p2000
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: 2580
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2580
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 3113
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2442, 3113
Unit selection: -
Expert list: 1
Factory setting
0