p50483[0...n]

Oscillation setpoint 2 time / Oscill set 2 t

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.1 [s]
Description:
Sets the time during which setpoint 2 should be applied for the square-wave generator.
Dependency:
Refer to: p50480, p50481, p50482
p50484[0...n]

CI: Oscillation signal source for default setpoint / Oscill def set

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the default setpoint for oscillation.
This setpoint is injected when the "Oscillate" function is not selected.
Dependency:
Refer to: p50485
p50485[0...n]

BI: Oscillation selection of signal source / Oscill sel sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the selection of the "Oscillate" function.
Dependency:
Refer to: p50480, p50481, p50482, p50483, p50484
Note:
BI: p50485 = 0 signal
Oscillation is not selected. The default setpoint is applied (CI: p50484).
BI: p50485 = 1 signal
Oscillation is selected. The square-wave generator is active (p50480, p50481, p50482, p50483).
p50486

BI: Motor interface signal source for brush length / Mot br l sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for triggering fault F60025 "Brush length".
Dependency:
Refer to: r53120
Refer to: F60025
Note:
The fault is triggered with a delay.
The signal is available via binector output r53210.0 for further interconnection.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
300.0 [s]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 3120
Unit selection: -
Expert list: 1
Factory setting
0.1 [s]
Access level: 2
Func. diagram: 3120
Unit selection: -
Expert list: 1
Factory setting
52209[0]
Access level: 2
Func. diagram: 3120
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 8035
Unit selection: -
Expert list: 1
Factory setting
0
465