2 Parameters
2.2 List of parameters
p2099[0...1]

CI: Connector-binector converter signal source / Con/bin S_src

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32 / Integer16
CU_DC_S, DC_CTRL,
P-Group: Communications
DC_CTRL_R,
Not for motor type: -
DC_CTRL_R_S,
DC_CTRL_S
Min
-
Description:
Sets the signal source for the connector-binector converter.
A PZD receive word can be selected as signal source. The signals are available to be serially passed-on
(interconnection).
Dependency:
Refer to: r2094, r2095
Note:
From the signal source set via the connector input, the corresponding lower 16 bits are converted.
p2099[0...1] together with r2094.0...15 and r2095.0...15 forms two connector-binector converters:
Connector input p2099[0] to binector output in r2094.0...15
Connector input p2099[1] to binector output in r2095.0...15
p2099[0...1]
CI: Connector-binector converter signal source / Con/bin S_src
TM150, TM15DI_DO,
Can be changed: U, T
TM31
Data type: Unsigned32 / Integer16
P-Group: Communications
Not for motor type: -
Min
-
Description:
Sets the signal source for the connector-binector converter.
A PZD receive word can be selected as signal source. The signals are available to be serially passed-on
(interconnection).
Dependency:
Refer to: r2094, r2095
Note:
From the signal source set via the connector input, the corresponding lower 16 bits are converted.
p2099[0...1] together with r2094.0...15 and r2095.0...15 forms two connector-binector converters:
Connector input p2099[0] to binector output in r2094.0...15
Connector input p2099[1] to binector output in r2095.0...15
p2100[0...19]
Change fault response fault number / Chng resp F_no
CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S, DC_CTRL,
P-Group: Messages
DC_CTRL_R,
Not for motor type: -
DC_CTRL_R_S,
DC_CTRL_S
Min
0
Description:
Selects the faults for which the fault response should be changed
Dependency:
The fault is selected and the required response is set under the same index.
Refer to: p2101
Note:
Re-parameterization is also possible if a fault is present. The change only becomes effective after the fault has been
resolved.
162
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: 2460, 2481
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2468
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 8075
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS DCM