p3101[0...1]

RTC set UTC time / RTC set UTC

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Setting the UTC time.
This means that the drive system is synchronized to the time specified by the time master.
To start p3101[1] must be written to followed by p3101[0]. After writing to p3101[0], the UTC time is accepted.
p3101[0]: Milliseconds
p3101[1]: Days
r3102[0...1]
RTC read UTC time / RTC read UTC
CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the actual UTC time in the drive system.
p3102[0]: Milliseconds
p3102[1]: Days
p3103

RTC synchronization source / RTC sync_source

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the synchronization source/technique.
Value:
0:
1:
2:
3:
p3104

BI: RTC real time synchronization PING / RTC PING

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32 / Binary
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the PING event to set the UTC time.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
PROFIBUS
PROFINET
PPI
PROFINET PTP
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4294967295
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
199