p4831

Function generator amplitude scaling / FG amplitude scal

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0.00000 [%]
Description:
Sets the scaling for the amplitude of the signal waveforms for all output channels.
The value can be changed while the function generator is running.
p4832[0...2]
Function generator amplitude scaling / FG amplitude scal
CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
-340.28235E36 [%]
Description:
Sets the scaling for the amplitude of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
p4833[0...2]

Function generator offset scaling / FG offset scal

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
-340.28235E36 [%]
Description:
Sets the scaling for the offset of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
r4834[0...4]
CO: Function generator free measurement output signal / FG fr MeasFct outp
CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
- [%]
Description:
Displays the output signal for the free measurement function.
Index:
[0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Dependency:
Refer to: p4810
Note:
The signals are only output in the "free measurement function" operating mode (p4810 = 6)
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
200.00000 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
340.28235E36 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
340.28235E36 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
100.00000 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
100.00000 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
100.00000 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
- [%]