2 Parameters
2.1 Overview of parameters
Parameter values
Min.
Max
Factory setting
Not for motor type
This information is of no relevance for SINAMICS DC MASTER.
Scaling
Specification of the reference variable with which a signal value is automatically converted for
a BICO interconnection.
The following reference variables are available:
• p2000 ... p2007: Reference speed, reference voltage, etc.
• PERCENT: 1.0 = 100 %
• 4000H: 4000 hex = 100 %
Expert list
Specifies whether this parameter is available in the expert list of the specified drive objects in
the commissioning software.
1: Parameter is available in the expert list.
0: Parameter is not available in the expert list.
NOTICE
Users are responsible for using parameters that are marked "Expert list: 0" (parameter not
included in the expert list).
These parameters and their functionalities have not been tested and no further user
documentation is available for them (e.g. description of functions). Moreover,
"Technical Support" (hotline) does not provide any support for these parameters.
22
Minimum value of the parameter [unit]
Maximum value of the parameter [unit]
Value when delivered [unit]
In the case of a binector/connector input, the signal source of the
default BICO interconnection is specified. A non-indexed
connector output is assigned the index [0].
List Manual (LH8), 02/2015, 6RX1800-0ED76
SINAMICS DCM