Co/Bo: Device Fan State / Dev Fan State; Device Fan Present / Device_Fan Pres; Co/Bo: Fan And External Fault / Fan Ext F - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r53135.0...12

CO/BO: Device fan state / Dev fan state

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output/binector output for the state of the device fan.
Bit field:
Bit
00
01
08
09
10
11
12
Dependency:
Refer to: p50082, p50096
Refer to: F60167
Note:
Dependent upon the order number (MLFB), the fan configuration may be as follows:
- No fans
- 2 DC fans
- 1 AC fan
Re bits 8 ... 11:
These bits are not effective on the Control Module.
Re bit 12:
This bit is only effective on the Control Module.
r53136

Device fan present / Device_fan pres

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the integrated device fan.
Bit field:
Bit
00
01
02
03
04
Note:
For the Control Module, fan "available" is always displayed as the Control Module only has one output to control the
fan.
The display is independent of the state of the fan and only indicates the desired state.
r53140.0...4

CO/BO: Fan and external fault / Fan ext F

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output of the state of the fan and external fault for the Control Module.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
Switch on fan
Switch on fan inverted
Fan 1 speed OK
Fan 2 speed OK
Fan 3 speed OK
Fan 4 speed OK
Control Module fan speed OK
Signal name
DC fan 1
DC fan 2
AC fan 1
AC fan 2
Control Module fan
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
ON
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Available
Available
Available
Available
Available
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF
OFF
No (too low)
No (too low)
No (too low)
No (too low)
No
Access level: 2
Func. diagram: 6960
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Not present
Not present
Not present
Not present
Not present
Access level: 2
Func. diagram: 8049
Unit selection: -
Expert list: 1
Factory setting
-
FP
8047
8047
8047
8047
8047
8047
8049
FP
6960
6960
6960
6960
6960
635

Hide quick links: