p8848

IF2 PZD sampling time / IF2 PZD t_sample

CU_DC, CU_DC_R,
Can be changed: C1(3)
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Communications
Not for motor type: -
Min
1.00 [ms]
Description:
Sets the sampling time for the cyclic interface 2 (IF2).
Note:
The system only permits certain sampling times and after writing to this parameter, displays the value that has
actually been set.
For clock cycle synchronous operation, the specified bus cycle time applies (Tdp).
r8849[0...139]

COMM BOARD receive configuration data / CB r config_dat

CU_DC (PROFINET
Can be changed: -
CBE20), CU_DC_R
Data type: Unsigned16
(PROFINET CBE20),
P-Group: Communications
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
-
Description:
Displays the receive configuration data for the COMM BOARD.
r8850[0...63]

CO: IF2 PZD receive word / IF2 PZD recv word

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Integer16
DC_CTRL_R_S,
DC_CTRL_S
P-Group: Communications
Not for motor type: -
Min
-
Description:
Connector output for interconnecting the PZD (setpoints) received via interface 2 in the word format.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
[16] = PZD 17
[17] = PZD 18
[18] = PZD 19
[19] = PZD 20
[20] = PZD 21
[21] = PZD 22
[22] = PZD 23
[23] = PZD 24
[24] = PZD 25
[25] = PZD 26
[26] = PZD 27
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
16.00 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: 4000H
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
4.00 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 2485, 9204,
9206
Unit selection: -
Expert list: 1
Factory setting
-
319