Cbe2X Interface Configuration / Cbe2X Int Config; Cbe2X Name Of Station Active / Cbe2X Name Act; Cbe2X Ip Address Of Station Active / Cbe2X Ip Act - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
If value = 0:
DHCP deactivated.
If value = 1:
Reserved.
If value = 2:
DHCP activated. The MAC address of this interface is used for client identification.
If value = 3:
DHCP activated. The station name of this interface is used for client identification.
p8945

CBE2x interface configuration / CBE2x int config

CU_DC (PROFINET
Can be changed: U, T
CBE20), CU_DC_R
Data type: Integer16
(PROFINET CBE20),
P-Group: -
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
0
Description:
Sets the activation of the interface configuration for the Communication Board Ethernet 20/25 (CBE20/CBE25).
p8945 is automatically set to 0 at the end of an operation.
Value:
0:
2:
3:
Dependency:
Refer to: p8940, p8941, p8942, p8943, p8944
Notice:
When the DHCP mode is active (p8944 > 0), then PROFINET communication via this interface is no longer possible!
However, the interface can be used by the STARTER/SCOUT commissioning tool.
Note:
For CBE20, the parameter is only valid for firmware version "PROFINET Device" (p8835 = 1) or "Ethernet/IP" (p8835
= 4). Otherwise, it is locked.
This restriction is not applicable for the CBE25.
Re p8945 = 2:
The interface configuration (p8940 and following) is saved and activated after the next POWER ON.
Re p8945 = 3:
The factory setting of the interface configuration is loaded after the next POWER ON.
r8950[0...239]

CBE2x Name of Station active / CBE2x Name act

CU_DC (PROFINET
Can be changed: -
CBE20), CU_DC_R
Data type: Unsigned8
(PROFINET CBE20),
P-Group: -
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
-
Description:
Displays the active station name for the Communication Board Ethernet 20/25 (CBE20/CBE25).
r8951[0...3]

CBE2x IP Address of Station active / CBE2x IP act

CU_DC (PROFINET
Can be changed: -
CBE20), CU_DC_R
Data type: Unsigned8
(PROFINET CBE20),
P-Group: -
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
0
Description:
Displays the active IP address for the Communication Board Ethernet 20/25 (CBE20/CBE25).
346
No function
Save and activate configuration
Delete configuration
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-