For the components that have been replaced, the electronic rating plate must match as far as the following data is
concerned:
- component type (e.g. "SMC20")
- Order No. (e.g. "6SL3055-0AA0-5BA0")
For p9909 = 0, serial numbers and hardware versions are not automatically transferred. In this case, the transfer
must be made using p9904.
Dependency:
Refer to: p9904, p9905
Note:
The modified target topology is automatically saved in a non-volatile fashion when the drive object runs-up (e.g. after
a POWER ON).
Special case for Control Unit and option slot modules:
When replacing these components, independent of p9909, the serial number and hardware version are automatically
transferred and saved in a non-volatile fashion.
p9910

Target topology accept additional components / Add comp accept

CU_DC, CU_DC_R,
Can be changed: C1(1)
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Topology
Not for motor type: -
Min
0
Description:
Accept additional inserted DRIVE-CLiQ components into the target topology.
The corresponding drive objects are added to the project.
Value:
0:
1:
p9915
DRIVE-CLiQ data transfer error shutdown threshold master / DQ fault master
CU_DC, CU_DC_R,
Can be changed: C1(1)
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Topology
Not for motor type: -
Min
0000 hex
Description:
Only for internal Siemens service purposes.
p9916
DRIVE-CLiQ data transfer error shutdown threshold slave / DQ fault slave
CU_DC, CU_DC_R,
Can be changed: C1(1)
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Topology
Not for motor type: -
Min
0000 hex
Description:
Only for internal Siemens service purposes.
p9920[0...99]

Licensing enter license key / Enter license key

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned8
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Enters the license key for this drive unit.
Example of the license key:
EACZ-QBCA = 69 65 67 90 45 81 66 67 65 dec (ASCII characters)
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
No selection
Transfer components
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
0007 07FF hex
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
0007 07FF hex
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0007 02FF hex
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0007 02FF hex
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
363