2 Parameters
2.2 List of parameters
p0007

BOP background lighting / BOP lighting

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: -
Not for motor type: -
Min
0 [s]
Description:
Sets the delay time until the background lighting of the Basic Operator Panel (BOP) is switched off.
If no keys are actuated, then the background lighting automatically switches itself off after this time has expired.
Note:
p0007 = 0: Background lighting is always switched on (factory setting).
p0008

BOP drive object after booting / BOP DO after boot

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: -
Not for motor type: -
Min
1
Description:
Sets the required drive object that is active at the Basic Operator Panel (BOP) after booting.
Note:
The value from p0008 initializes the display on the Basic Operator Panel (BOP) at the top left after booting.
The drive object Control Unit is selected using the value 1.
p0009

Device commissioning parameter filter / Dev comm par_filt

CU_DC, CU_DC_R,
Can be changed: C1, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the device and basic drive commissioning.
By appropriately setting this parameter, those parameters are filtered that can be written into in the various
commissioning steps.
Value:
0:
1:
2:
3:
4:
29:
30:
50:
55:
Notice:
For p0009 = 10000 the following applies:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
Note:
The drives can only be powered up outside the device commissioning (the drive enabled). In this case, p0009 must
be 0 (Ready) and the individual drive objects must have already gone into operation (p0010).
p0009 = 1: Device configuration
At the first commissioning of the device, after booting, the device is in the "device configuration" state. To start the
internal automatic first commissioning of the drive unit, p0009 should be set to 0 (Ready) after the ID for the actual
topology (r0098) was transferred into the ID for the target topology (p0099). To do this, it is sufficient to set a single
index value of p0099[x] the same as r0098[x]. Before the device has been completely commissioned, no other
parameter can be changed. After the first commissioning was carried out, in this state, when required, other basic
device configuration parameters can be adapted (e.g. the basic sampling time in p0110).
34
Ready
Device configuration
Defining the drive type/function module
Drive base configuration
Data set base configuration
Device download
Parameter reset
OA application configuration
OA application installation
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2000 [s]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
55
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0 [s]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
SINAMICS DCM