Bico Interconnections Bi/Ci Parameters / Bico Bi/Ci Par; Bico Interconnections Search Signal Source / Bico S_Src Srch; Bico Interconnections Bo/Co Parameters / Bico Bo/Co Par; Bico Interconnections Signal Source Search Count / Bico S_Src Srchqty - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r9482[0...n]

BICO interconnections BI/CI parameters / BICO BI/CI par

All objects
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the signal sinks (binector/connector inputs, BI/CI parameters).
The number of BICO interconnections is displayed in r9481.
Dependency:
Refer to: r9481, r9483
Note:
The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal sink, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal sink, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
r9483[0...n]

BICO interconnections BO/CO parameters / BICO BO/CO par

All objects
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the signal sources (binector/connector outputs, BO/CO parameters).
The number of BICO interconnections is displayed in r9481.
Dependency:
Refer to: r9481, r9482
Note:
The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal sink, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal sink, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
p9484

BICO interconnections search signal source / BICO S_src srch

All objects
Can be changed: U, T
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the signal source (BO/CO parameter, BICO coded) to search in the signal sinks.
The question is answered:
How often is a connection made to a signal source in the drive object and from which index are these
interconnections saved (r9482 and r9483)?
Dependency:
Refer to: r9481, r9482, r9483, r9485, r9486
r9485

BICO interconnections signal source search count / BICO S_src srchQty

All objects
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the number of BICO interconnections to the signal sink being searched for.
Dependency:
Refer to: r9481, r9482, r9483, p9484, r9486
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: r9481
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: r9481
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4294967295
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
355