Redundant Coarse Position Value Configuration / Red Pos Config; Gx_Xist1 Coarse Position Safe Most Significant Bit / Gx_Xist1 Safe Msb; Co: Measuring Gear Position Difference / Meas Gear Pos Diff; Co: Diagnostics Encoder Position Actual Value Gn_Xist1 / Diag Gn_Xist1 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r0474[0...2]

Redundant coarse position value configuration / Red pos config

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the encoder configuration for the redundant coarse position value.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = -
Bit field:
Bit
00
01
02
04
r0475[0...2]

Gx_XIST1 coarse position safe most significant bit / Gx_XIST1 safe MSB

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned16
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the bit number for the safe most significant bit (MSB) of the Gx_XIST1 coarse position.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = -
Note:
MSB: Most Significant Bit
r0477[0...2]

CO: Measuring gear position difference / Meas gear pos diff

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Integer32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the position difference before the measuring gear between powering down and powering up.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = -
Note:
The increments are displayed in the format the same as r0483. The position difference should be read in encoder
increments.
r0479[0...2]

CO: Diagnostics encoder position actual value Gn_XIST1 / Diag Gn_XIST1

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Integer32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Display and connector output for the encoder actual position value Gn_XIST1 according to PROFIdrive for
diagnostics.
86
Signal name
Incrementer
Encoder CRC least significant byte first
Redundant coarse position val. most
significant bit left-aligned
Binary comparison not possible
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 4704
Unit selection: -
Expert list: 1
Factory setting
-