r50052

Optimization run status / Opt run status

DC_CTRL
Can be changed: -
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Displays the status during the optimization run.
Value:
0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
101:
102:
103:
201:
202:
203:
204:
301:
302:
401:
402:
403:
404:
405:
406:
407:
408:
409:
410:
411:
412:
413:
414:
415:
416:
417:
418:
419:
420:
421:
422:
423:
424:
425:
426:
501:
502:
503:
504:
505:
506:
507:
508:
509:
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
No optimization run
Wait for operating state 7.4
Check prerequisites
Save original interconnection
Interconnect optimization parameters
Wait for operating state 0.x or 1.5
Set optimized parameter values
Wait for operating state 8.0
Troubleshooting
Exit optimization run
Set field current to 100%
Measure field circuit resistance
Measure field circuit inductance
Wait for field decay
Set armature current to 100%
Measure armature circuit resistance
Measure armature circuit inductance
Record speed characteristic
Stop motor
Calculate nominal EMF
Calculate nominal speed
Record field characteristic 91 % field current
Record field characteristic 83 % field current
Record field characteristic 76 % field current
Record field characteristic 70 % field current
Record field characteristic 65 % field current
Record field characteristic 60.5 % field current
Record field characteristic 56.5 % field current
Record field characteristic 53 % field current
Record field characteristic 50 % field current
Record field characteristic 47 % field current
Record field characteristic 44 % field current
Record field characteristic 41 % field current
Record field characteristic 38 % field current
Record field characteristic 35 % field current
Record field characteristic 32 % field current
Record field characteristic 29 % field current
Record field characteristic 26 % field current
Record field characteristic 23 % field current
Record field characteristic 20 % field current
Record field characteristic 17 % field current
Record field characteristic 14 % field current
Record field characteristic 11 % field current
Record field characteristic 8% field current
Recording of field characteristic is complete
Wait for field to build up
Recording the friction characteristic - 10% rated speed
Recording the friction characteristic - 20% rated speed
Recording the friction characteristic - 30% rated speed
Recording the friction characteristic - 40% rated speed
Recording the friction characteristic - 50% rated speed
Recording the friction characteristic - 60% rated speed
Recording the friction characteristic - 70% rated speed
Recording the friction characteristic - 80% rated speed
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
701
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 2660
Unit selection: -
Expert list: 1
Factory setting
-
385