r2294
CO: Technology controller output signal / Tec_ctrl outp_sig
DC_CTRL (Tech_ctrl),
Can be changed: -
DC_CTRL_R
Data type: FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
- [%]
Description:
Display and connector output for the output signal of the technology controller.
Dependency:
Refer to: p2295
p2295
CO: Technology controller output scaling / Tec_ctrl outp scal
DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
-100.00 [%]
Description:
Sets the scaling for the output signal of the technology controller.
p2296[0...n]
CI: Technology controller output scaling / Tec_ctrl outp scal
DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: Unsigned32 / FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
-
Description:
Sets the signal source for the scaling value of the technology controller.
Dependency:
Refer to: p2295
p2297[0...n]
CI: Technology controller maximum limit signal source / Tec_ctrMaxLimS_src
DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: Unsigned32 / FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
-
Description:
Sets the signal source for the maximum limiting of the technology controller.
Dependency:
Refer to: p2291
p2298[0...n]
CI: Technology controller minimum limit signal source / Tec_ctrl min_l s_s
DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: Unsigned32 / FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
-
Description:
Sets the signal source for the minimum limiting of the technology controller.
Dependency:
Refer to: p2292
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
100.00 [%]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
2295[0]
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
2291[0]
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
2292[0]
189