2.2 List of parameters
p2299[0...n]

CI: Technology controller limit offset / Tech_ctrl lim offs

DC_CTRL (Tech_ctrl),
Can be changed: U, T
DC_CTRL_R
Data type: Unsigned32 / FloatingPoint32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
-
Description:
Sets the signal source for the offset of the output limiting of the technology controller.
p2306

Technology controller fault signal inversion / Tec_ctrl fault inv

DC_CTRL (Tech_ctrl),
Can be changed: T
DC_CTRL_R
Data type: Integer16
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
0
Description:
Setting to invert the fault signal of the technology controller.
The setting depends on the type of control loop.
Value:
0:
1:
Caution:
If the actual value inversion is incorrectly selected, then the closed-loop control with the technology controller can
become unstable and can oscillate!
Note:
The correct setting can be determined as follows:
- inhibit the technology controller (p2200 = 0).
- increase the motor speed and in so doing, measure the actual value signal (of the technology controller).
- if the actual value increases with increasing motor speed, then the inversion should be switched out.
- if the actual value decreases with increasing motor speed, then the inversion should be set.
If value = 0:
The drive reduces the output speed when the actual value rises (e.g. for heating fans, intake pump, compressor).
If value = 1:
The drive increases the output speed when the actual value increases (e.g. for cooling fans, discharge pumps).
r2349.0...11

CO/BO: Technology controller status word / Tec_ctrl status

DC_CTRL (Tech_ctrl),
Can be changed: -
DC_CTRL_R
Data type: Unsigned32
(Tech_ctrl),
P-Group: Technology
DC_CTRL_R_S
Not for motor type: -
(Tech_ctrl),
DC_CTRL_S
Min
(Tech_ctrl)
-
Description:
Displays the status word of the technology controller.
Bit field:
Bit
00
01
02
03
08
09
190
No inversion
Inversion
Signal name
Technology controller de-activated
Technology controller limited
Technology controller motorized
potentiometer limited max
Technology controller motorized
potentiometer limited min
Technology controller actual value at the
minimum
Technology controller actual value at the
maximum
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 7958
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No