2 Parameters
2.2 List of parameters
p51608[0...n]

Setpoint processing reduction factor / Red factor

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the reduction factor for the speed setpoint in the context of setpoint processing.
Dependency:
Dependent upon binector input (p51607):
1 signal:
The reduction factor (p51608) is not applied (r52194 = r52195).
0 signal:
The reduction factor (p51608) is applied (r52194 = r52195 x p51608).
Refer to: p51607, r52194, r52195
p51616

E stop response / E stop response

DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the response of the control to the triggering of an E stop.
Value:
0:
1:
Note:
If value = 0:
E stop has the same effect as OFF2.
If value = 1:
E stop interrupts the firing pulse sequence immediately. The process does not wait for Ia = 0 and Alpha W pulses are
not emitted.
p51618

LOCAL mode enable behavior / LOCAL enab behav

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the behavior for enable via terminal X177.13 in the LOCAL mode.
Value:
0:
1:
p51619[0...n]

BI: Signal source for switching on line contactor / Line cont ON sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the "Line contactor ON" relay output (XR1.109/110).
536
E stop has the same effect as OFF2
E stop triggers immediate pulse inhibit
Terminal X177.13 is not effective in the LOCAL mode
Terminal X177.13 is effective in the LOCAL mode
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
15.00 [%]
Access level: 2
Func. diagram: 2070
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2580
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2070
Unit selection: -
Expert list: 1
Factory setting