Co/Bo: Control Word Faults/Alarms / Stw Fault/Alarm; Co/Bo: Status Word Faults/Alarms 1 / Zsw Fault/Alarm 1 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r2138.7...15

CO/BO: Control word faults/alarms / STW fault/alarm

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S, DC_CTRL,
DC_CTRL_R,
P-Group: Displays, signals
DC_CTRL_R_S,
Not for motor type: -
DC_CTRL_S
Min
-
Description:
Display and BICO output for the control word of faults and alarms.
Bit field:
Bit
07
10
11
12
13
14
15
Dependency:
Refer to: p2103, p2104, p2105, p2106, p2107, p2108, p2112, p2116, p2117, p3110, p3111, p3112
r2138.7...15
CO/BO: Control word faults/alarms / STW fault/alarm
TM150, TM15DI_DO,
Can be changed: -
TM31
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Display and BICO output for the control word of faults and alarms.
Bit field:
Bit
07
10
11
12
13
14
15
Dependency:
Refer to: p2103, p2104, p2105, p2106, p2107, p2108, p2112, p2116, p2117, p3110, p3111, p3112
r2139.0...15

CO/BO: Status word faults/alarms 1 / ZSW fault/alarm 1

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S, DC_CTRL,
DC_CTRL_R,
P-Group: Displays, signals
DC_CTRL_R_S,
Not for motor type: -
DC_CTRL_S
Min
-
Description:
Display and BICO output for status word 1 of faults and alarms.
Bit field:
Bit
00
01
03
05
06
07
08
11
12
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
Acknowledge fault
External alarm 1 (A07850) effective
External alarm 2 (A07851) effective
External alarm 3 (A07852) effective
External fault 1 (F07860) effective
External fault 2 (F07861) effective
External fault 3 (F07862) effective
Signal name
Acknowledge fault
External alarm 1 (A07850) effective
External alarm 2 (A07851) effective
External alarm 3 (A07852) effective
External fault 1 (F07860) effective
External fault 2 (F07861) effective
External fault 3 (F07862) effective
Signal name
Being acknowledged
Acknowledgment required
Fault present
Safety message present
Internal message 1 present
Alarm present
Internal message 2 present
Alarm class bit 0
Alarm class bit 1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
High
High
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 2546, 8060,
8065
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
Access level: 2
Func. diagram: 2546
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
Access level: 2
Func. diagram: 2548, 8060,
8065
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
Low
Low
FP
8060
8065
8065
8065
8060
8060
8060
FP
8060
8065
8065
8065
8060
8060
8060
FP
-
-
8060
-
-
8065
-
-
-
179