Reset Bico Interconnections To Other Drives / Reset Bico To Drv; Bico Behavior For De-Activated Drive Objects / Behav For Deact Do; Bico Behavior When Activating Drive Objects / Behav When Act Do - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
p9493[0...9]

Reset BICO interconnections to other drives / Reset BICO to drv

All objects
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to reset the BICO interconnections to other drives.
Each interconnection can be individually reset.
Value:
0:
1:
2:
15:
Dependency:
Refer to: r9490, r9491, r9492
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
p9495

BICO behavior for de-activated drive objects / Behav for deact DO

All objects
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the behavior for BICO interconnections to drive objects that are either not capable of operation or have been
deactivated.
BO/CO parameters are on the drive object that is either not capable of operation or has been deactivated (signal
source).
Value:
0:
1:
2:
Dependency:
Refer to: p9496, p9497, p9498, p9499
Note:
For p9495 = 0, the following applies:
- the number of interconnections is zero (p9497 = 0).
For p9495 not equal to 0, the following applies:
- the BI/CI parameters involved are listed in p9498[0...29] (signal sink).
- the associated BO/CO parameters are listed in p9499[0...29] (signal source).
p9496

BICO behavior when activating drive objects / Behav when act DO

All objects
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the behavior when activating BICO interconnections to drive objects that are either not capable of operation or
have been deactivated.
Value:
0:
1:
2:
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Set connection to 0
Set connection to 1 (100 %)
Set connection to factory setting
Finished
Inactive
Save interconnections
Save interconnections and establish the factory setting
Inactive
Restore the interconnections from the list
Delete the interconnections from the list
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
15
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
15
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
357

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents