Function generator physical address / FG phys address

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0
Description:
Sets the physical address where the function generator is to be connected.
Dependency:
Only effective when p4810 = 99.
p4813

Function generator physical address reference value / FG phys addr ref

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
1.00
Description:
Sets the reference value for 100 % for referred inputs.
Dependency:
Only effective when p4810 = 99.
p4816
Function generator output signal integer number scaling / FG outp integ scal
CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer32
CU_DC_S
P-Group: -
Not for motor type: -
Min
-2147483648
Description:
Sets the scaling for the integer number of the output signal for the function generator.
Dependency:
Refer to: r4805, r4817
Note:
The parameter can only be changed in the following operating states:
r4805 = 0, 4, 6
r4817
CO: Function generator output signal integer number / FG outp integ no.
CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Integer32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
-
Description:
Display and connector output for the integer number of the output signal for the function generator.
Dependency:
Refer to: p4816
Note:
The value is output independent of the function generator operating mode.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Connection at connector output r4818
Connection at current setpoint after filter and r4818
Connection as disturbing torque and r4818
Connection at speed setpoint after filter and r4818
Connection at current setpoint before filter and r4818
Connection at speed setpoint before filter and r4818
Connection for free measurement function r4818 and r4834
Connection at physical address and r4818
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4294967295
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1000000.00
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2147483647
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
1.00
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
277