Co: Speed Controller Proportional Component Output Value; Co: Speed Controller Integral Component Output Value; Co: Speed Controller Setpoint/Actual Value Difference - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r52161
CO: Speed controller proportional component output value / P comp outp val
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the output value of the proportional component on the speed controller.
r52162
CO: Speed controller integral component output value / I_comp outp val
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the integral component of the speed controller's output value.
r52164
CO: Speed controller setpoint/actual value difference / n_ctr set/act dif
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of the speed setpoint/actual value difference used for the speed controller.
Dependency:
Refer to: p50620
r52165
CO: Speed controller setpoint/actual value difference / n_ctr set/act dif
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the result of the setpoint/actual value difference on the speed controller.
Dependency:
Refer to: p50621, p50622, p50623, p50624
Note:
The setpoint/actual value difference (r52165) results from setpoint 1 and 2 (p50621, p50622) and actual value 1 and
2 (p50623, p50624).
r52166
CO: Speed controller actual value selection absolute value / Sel act abs
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output of the selected speed actual value as an absolute value on the speed controller.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6815
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6815
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6815, 6820
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6810
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6810, 6815,
6825, 6900, 8040, 8046
Unit selection: -
Expert list: 1
Factory setting
- [%]