2 Parameters
2.2 List of parameters
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The speed actual value is available smoothed (r0021, r0022, r0063[1] with p0045) and unsmoothed (r0063[0]).
r0027

CO: Absolute actual current smoothed / I_act abs val smth

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [A]
Description:
Displays the smoothed absolute actual current value.
Dependency:
Refer to: p0045, r0068
Notice:
This smoothed signal is not suitable for diagnostics or evaluation of dynamic operations. In this case, the
unsmoothed value should be used.
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The absolute value of the current actual value is available smoothed (r0027, r0068[1] with p0045) and unsmoothed
(r0068[0]).
r0031

Actual torque smoothed / M_act smooth

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [Nm]
Description:
Displays the smoothed torque actual value.
Dependency:
Refer to: p0045, r0080
Note:
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The torque actual value is available smoothed (r0031, r0080[1] with p0045) and unsmoothed (r0080[0]).
r0032

CO: Active power actual value smoothed / P_actv_act smth

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [kW]
Description:
Displays the smoothed actual value of the active power.
Notice:
This smoothed signal is not suitable for diagnostics or evaluation of dynamic operations. In this case, the
unsmoothed value should be used.
Note:
Smoothing time constant = 100 ms
The active power is available smoothed (r0032, r0082[1] with p0045) and unsmoothed (r0082[0]).
40
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: -
Unit group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dyn. index: -
Unit group: 14_10
Scaling: r2004
Max
- [kW]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 6850
Unit selection: -
Expert list: 1
Factory setting
- [A]
Access level: 2
Func. diagram: 6850
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 2
Func. diagram: 2450
Unit selection: p0505
Expert list: 1
Factory setting
- [kW]