Sensor Module Filter Bandwidth Display / Sm Filt_Bandw Disp; Analog Sensor Lvdt Ratio / An_Sens Lvdt Ratio; Analog Sensor Lvdt Phase / An_Sens Lvdt Ph; Zero Mark Monitoring Tolerance Permissible / Zm_Monit Tol Perm - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r4661[0...2]

Sensor Module filter bandwidth display / SM Filt_bandw disp

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
- [kHz]
Description:
Display of the effective filter bandwidth for Sensor Module SMx10 (resolver) and SMx20 (sin/cos).
The bandwidth of the filter is set using p4660.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p4660
Note:
A value of zero is displayed if an encoder is not present.
p4678[0...n]

Analog sensor LVDT ratio / An_sens LVDT ratio

DC_CTRL,
Can be changed: C2(4)
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
0.00 [%]
Description:
Sets the ratio for the LVDT sensor.
p4679[0...n]

Analog sensor LVDT phase / An_sens LVDT ph

DC_CTRL,
Can be changed: C2(4), T
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-360.00 [°]
Description:
Sets the phase for the LVDT sensor.
p4680[0...n]

Zero mark monitoring tolerance permissible / ZM_monit tol perm

DC_CTRL,
Can be changed: C2(4)
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Sets the permissible tolerance in encoder pulses for the zero mark distance in the context of zero mark monitoring.
Causes fault F3x100 to appear less frequently.
p4681[0...n]
Zero mark monitoring tolerance window limit 1 positive / ZM tol lim 1 pos
DC_CTRL,
Can be changed: C2(4)
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Sets the positive tolerance window in encoder pulses for limit 1 for the zero mark monitoring.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [kHz]
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
200.00 [%]
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
360.00 [°]
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
1000
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
1000
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [kHz]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
50.00 [%]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [°]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
4
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2